Accusys ACS-77100 Instrukcja Użytkownika Strona 21

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 30
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 20
http://www.accusys.com.tw
20
User’s Manual
4.1.5. Rebuild Messages
LCD Display Message
Rebuilding data to a new disk (Disk X) since Disk X
failure.
Disk rebuild completed successfully.
The capacity of the new disk (Disk X) is too small.
XXX GB is the capacity of the new disk.
DX Rebuild XX.X%
Total: XXX GB
DX Rebuild 100%
XXX GB OK!
YYY GB is the minimum disk capacity of the RAID.
DX Rebuild Fail
XX GB < YYY GB
Disk rebuilding fail since Disk X failed.
DX Rebuild Fail
DX offline
Disk rebuilding fail since too many bad sectors in Disk X
DX Rebuild Fail
DX Bad sectors
4.1.6. Error Messages
RAID Failure Messages
LCD Display Message
The RAID failed since there are not enough disk
members.
RAID Fail
code: 0
The RAID failed since the sequence of the disks is
incorrect. The current sequence is displayed within the
< > space.
RAID Fail
code: 1 <xxxx>
The RAID has been failed, but all disks exist.
RAID Fail
code: 2
Przeglądanie stron 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 29 30

Komentarze do niniejszej Instrukcji

Brak uwag